MASH Test 3-11 of the W-Beam Guardrail on Low-Fill Box Culvert (405160-23-2)

Full-Text PDF

Author(s):

W.F. Williams, W.L. Menges

Publication Date:

November 2011

Abstract:

The primary objective of this study was to test and evaluate a guardrail design with standard post spacing for use across low-fill box culverts in accordance with MASH TL-3. A second objective of this study, was to develop a W 6x9 post with welded base plate detail for use with an epoxy anchoring system that would simplify installation. The crash test performed on the W-Beam Guardrail on Low-Fill Box Culvert was in accordance with test 3-11 MASH, which involves the 2270P vehicle (a 5000lb (1/2 ton) Quad Cab Pickup). Included in this report are the details of the installation used in the crash testing, details of the full-scale crash testing, and evaluation of the crash test. The W-Beam Guardrail on Low-Fill Box Culvert performed acceptably according to the specifications for MASH test 3-11.

Report Number:

405160-23-2

Keywords:

Guardrail, W-Beam, Culvert, Low-Fill, Longitudinal Barriers, Crash Test, Roadside Safety

Electronic Link(s):

Document/Product: http://www.roadsidepooledfund.org/files/2012/02/405160-23-2-box-culvert-rev2.pdf

Publication/Product Request

TTI reports and products are available for download at no charge. If an electronic version is not available and no instructions on how to obtain it are given, contact Publication Services at pubquest@ttimail.tamu.edu.